值: | Schneeberger 20 Readhead & Interpolation Box VF-x |
Schneeberger 2X Readhead & Interpolation Box VF-x |
Bosch-Rexroth MDC-1 |
Bosch-Rexroth VF-x |
P266 X LIN SCALE EN |
1 | 1 | 1 | 1 |
P266 X INVRT LN SCL |
1 | 0 | 0 | 0 |
P266 X NEG COMP DIR |
0 | 0 | 1 | 0 |
P267 Y LIN SCALE EN |
1 | 1 | 1 | 1 |
P267 Y INVRT LN SCL |
0 | 1 | 1 | 1 |
P267 Y NEG COMP DIR |
1 | 1 | 1 | 1 |
P268 Z LIN SCALE EN |
1 | 1 | 1 | 1 |
P268 Z INVRT LN SCL |
1 | 0 | 1 | 1 |
P268 Z NEG COMP DIR |
0 | 0 | 0 | 0 |
P125 X GRID OFFSET |
每台机器都独一无二 |
|||
P126 Y GRID OFFSET |
每台机器都独一无二 |
|||
P127 Z GRID OFFSET |
每台机器都独一无二 |
|||
P279 X LSC GAIN MULTIPLIER |
40 | 40 | 40 | 40 |
P280 Y LSC GAIN MULTIPLIER |
40 | 40 | 40 | 40 |
P281 Z LSC GAIN MULTIPLIER |
40 | 40 | 40 | 40 |
P285 X LSC OFFSET |
520000 |
520000 |
-200000 |
520000 |
P286 Y LSC OFFSET |
-763000 |
-763000 |
-200000 |
-763000 |
P287 Z LSC OFFSET |
590000 |
590000 |
250000 |
590000 |
P327 X LSC PER INCH |
25400 |
25400 |
26010 |
26010 |
P328 Y LSC PER INCH |
25400 |
25400 |
26010 |
26010 |
P329 Z LSC PER INCH |
25400 |
25400 |
26010 |
26010 |
P333 X LSC PER REV (Z pulse) |
50000 |
50000 |
51200 |
51200 |
P334 Y LSC PER REV |
50000 |
50000 |
51200 |
51200 |
P335 Z LSC PER REV |
50000 |
50000 |
51200 |
51200 |
Schneeberger integrated scales: 首先识别读头。不要将 2X 读头替换为 20 个读头。 必要时更改插值框 DIP 开关设置,以匹配每个轴使用的读取头。
20 Readhead: 使用 #50-0019 使用插值框并设置 DIP 开关:1°关、2°开、3°开、4°关、5°开、6°关、7°关、8°关。
2X Readhead: 使用 #50-0019A 使用插值框并设置 DIP 开关:1=开、2°关、3°关、4°关、5°关、6°开、7°关、8°关。
Bosch-Rexroth integrated scales: 读头不能从卡车上拆卸。此外,插值电子元件还集成到读头中。没有要调整的浸渍开关设置。
*此参数列表和值显示制造机床所使用的数据。始终使用参数检查程序分析参数。